Inputting Camera Images
Reference
Parameters
A= 1.00000
D= 0.00000
B= 0.00000
E= 1.00000
C=255.00000
F=241.00000
Sight= 512.000mm
OK
The initial Camera Settings Screen will be displayed.
Camera settings
2.
Select Calibration.
The initial Calibration Screen will be displayed.
Calibration(Camera0)
3.
Select Parameter input.
The Parameter Input Screen will be displayed.
Parameter input
4.
Make the settings for each item.
5.
Select End.
The settings will be registered and the screen in (2.) will return.
This screen is used to check data settings.
A to F represent the calibration conversion values. The camera
coordinates are converted to physical coordinates based on these
calibration conversion values. The formulae for conversion to
physical coordinates are as follows:
X' = A × X + B × Y + C
Y' = D × X + E × Y + F
(X,Y): measurement position (camera coordinates), unit: pixels
(X',Y'): conversion position (physical coordinates), units: mm
The physical unit for X direction on the screen
can be selected from
Shutter speed(Cam0)
Light control(Cam0)
Calibration(Cam0)
Shutter speed(Cam1)
Light control(Cam1)
Calibration(Cam1)
Shutter speed(Cam2)
Light control(Cam2)
Sampling input
Specifying point
Specifying coordinate axis
Parameter input
Reference parameter
Origin
:Upper left
Coordinate
:Left hand
Magnification
:[1.00000]
End
m, mm, cm, and m.
Section 2-1