Normal Serial Interface
Note If these settings are changed, one rectangular region will be set and any previ-
CHECK
Pattern Inspection (Settings Data)
Data
Settings
512
Accuracy
data
0: Normal
1: Precise
513
Verification
0: ON
1: OFF
514
Candidate level (0 to 99)
515
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
516
Region 0
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
Region 1
to
1524
Region 63
to
1539
ously drawn figures will be deleted. This is true for regions 1 to 63 as well.
Only the allocations for region 0 are listed here. Refer to the allocations for
region 0 to calculate the numbers for regions 1 to 63.
Details
Model position upper left X (0 to 511) (See note.)
Model position upper left Y (0 to 483) (See note.)
Model position lower right X (0 to 511) (See note.)
Model position lower right Y (0 to 483) (See note.)
Model reference position X (0 to 511)
Model reference position Y (0 to 483)
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to 483)
Correlation upper limit (0 to 100)
Correlation lower limit (0 to 100)
Position X upper limit (-9,999.999 to 9,999.999)
Position X lower limit (-9,999.999 to 9,999.999)
Position Y upper limit (-9,999.999 to 9,999.999)
Position Y lower limit (-9,999.999 to 9,999.999)
Model position upper left X (0 to 511) (See note.)
... (Same as for region 0)
Model position upper left X (0 to 511) (See note.)
... (Same as for region 0)
Position Y lower limit (-9,999.999 to 9,999.999)