Omron F250-UME Software Manual page 587

Table of Contents

Advertisement

Labeling
2-25-2
Setting the Binary Level
CHECK
Set the level for converting 256-gradation images into binary images. The
Controller performs measurement for the white pixels. Therefore, make the
settings so that the label measurement areas are white.
In this explanation, 3 circles on a measurement object will be used as an
example.
1.
Select Binary.
The screen for setting the binary level will be displayed.
2.
Move the cursor to the upper limit and use the Left and Right Keys to
change the value.
Binary level
↑ ↓:Move ←→:Change
Auto
The Controller automatically
sets the binary level
Right Key:
SHIFT + Right Keys: Increases the value in 10s.
Left Key:
SHIFT + Left Keys:
Up and Down Keys: Switches between setting items.
3.
Use the same method to change the lower value.
Set the upper and lower limits to make the area to be measured for labels
white.
Incorrect
4.
Select OK.
The settings will be registered and the screen in (1.) will return.
Measurement image
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Coordinate mode
Lower limit
Upper [255]
Lower [128]
Reverses dark and
white in the display
Increases the lowest digit by one.
Decreases the lowest digit by one.
Decreases the value in 10s.
Binary level
↑ ↓:Move ←→:Change
Section 2-25
Upper limit
Reverse
Auto
OK
Reverse
Upper [255]
Lower [128]
Reverse
Auto
OK
2-25-(4)