Binary Position Compensation
STEP 4: Re-registering Reference Values
STEP 5: Setting the Judgement Conditions
2-5-(9)
2.
Select either Correct or Clear and press the ENT Key.
If Correct is selected, the cursor will be displayed. Correct the size and po-
sition of the figure as desired.
If Clear is selected, the selected figure will be cleared.
This operation is performed when only the reference values are to be re-regis-
tered.
When a measurement region is drawn, the measurement is performed for the
displayed image and the results are registered as the reference values. If the
re-registering function explained here is used, only the reference values for the
image currently displayed will be registered. The area and center of gravity are
registered for the reference values.
1.
Select Reference registration.
Position0(Gravity and area)
A cursor will appear at the position of the center of gravity.
Reference registration
ENT:Set
2.
To change the position, use the Up/Down and Right/Left Keys to move
the cursor.
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
Make settings for the area and center of gravity.
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Measurement region
251,184
:Move
Section 2-5
Reference position