Omron F250-UME Software Manual page 541

Table of Contents

Advertisement

ECM Search
CHECK
CHECK
The registration selections will be displayed.
2.
Select Gravity.
The Binary Level Settings Screen will be displayed.
Binary level
:Move
Auto
The Controller automatically
determines binary level.
3.
Move the cursor to the upper limit and use the Left and Right Keys to
change the value.
Right Key:
SHIFT+Right Keys: Increases the value 10 times faster.
Left Key:
SHIFT+Left Keys:
Up and Down Keys: Switches between setting items.
4.
Use the same method to change the lower value.
Set the upper and lower limits so that the measurement object is displayed
as white pixels.
5.
Select OK.
The settings will be registered and the screen in (1.) will return.
A display cursor will appear at the center of gravity (search coordinates).
It is also possible to set the binary level so that measurement is performed
only for an intermediate density range.
Manual
Gravity
Edge
Lower limit
Upper[255]
Lower[128]
Reverse
Auto
OK
:Change
Reverse
Reverses white and
black in the display.
Increases the lowest digit by one.
Decreases the lowest digit by one.
Decreases the value 10 times faster.
Binary level
Upper[255]
Lower[128]
:Move
:Change
Section 2-23
Upper limit
Reverse
Auto
OK
2-23-(14)