Omron F250-UME Software Manual page 62

Table of Contents

Advertisement

Basic Operations
Defect Display
SeeAlso
1-(54)
This function is used to select the display method for defects or burrs.
The display will change depending on the settings for the defect inspection.
See page 1-(44).
Selection
Defect
inspection
method
Simple*
Labeling
Binary
Detail
Labeling
Binary
The asterisk (*) indicates the default setting.
Defect display position
The cursor will be
displayed at the center
of the set label.
The cursor will be
displayed at the center
of gravity of the defects.
If there is more than one
defect, the cursor will be
displayed at the center
of the white pixels, so it
may not be on a defect.
The set label will be
displayed in the NG
color.
All defects will be
displayed in the NG
color.