Normal Serial Interface
6-2-1
Setting Communications Specifications
CHECK
CHECK
Operational Flowcharts
RS-232C and RS-422 Connections
Note When the Flow control is set to Xon/off and a response is not received from
6-2-(2)
If the communications mode is set to Normal, the Controller can communicate
with an external device such as a personal computer through its serial inter-
face (with a RS-232C/RS-422 connection or Ethernet connection) using the
normal (no-protocol) format.
Set the output data under the Normal data results output processing item.
• Setting Mode
Command inputs are not received.
• Monitor Mode
Command inputs are received, but the measurement results are not out-
put to external devices. Only the command execution result (OK or ER) is
output.
When a command is input to read a set value, the appropriate value will
be output.
• Run Mode
Command inputs are received and measurement results are output.
After measurements have been made in Run Mode, the data up through
the last measurement will be output even if the mode is changed to another
mode. The data output will not be interrupted midway.
1:1 Connection
In the following example, a measurement command is input and those results
are read.
Controller
Execute measurement.
The parallel interface's BUSY signal will be ON during measuring.
Output processing
results.
the computer within the specified timeout time, a timeout error will occur
because the computer may be disconnected or malfunctioning. An error mes-
sage will be displayed on the Controller's screen and the parallel interface's
ERR signal will be turned ON.
Personal computer
Input command.
MEASURE
Receive measurement
results.