Omron F250-UME Software Manual page 202

Table of Contents

Advertisement

Model Position Compensation
2-8-5
Measurement Screens
SeeAlso
CHECK
Scroll Amount
Detailed Display
2-8-(14)
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for model
position compensation.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which model position com-
pensation is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the three
screens.
0.Scn 0
RUN
1.Model pos. comp
0
Judge:OK
ScrollX:256.321
ScrollY:269.213
Scroll : 20.0
The measurement values for each region will be displayed.
0.Scn 0
RUN
1.Model pos. comp
0
Corr.
: 93
Pos.X : 256.321
Pos.Y : 269.213
Angle θ:
2.236
Cand. :
1
RUN
Image status
:
Freeze(Before scroll)
Display image
: Image0
Image size
:
All
Display results
:
Details
End
OK 45ms
OK 45ms
Position above candidate level. Displayed
only when search verification set to ON.
Section 2-8
for details on Monitor and

Advertisement

Table of Contents
loading

Table of Contents