Omron F250-UME Software Manual page 648

Table of Contents

Advertisement

Calculation
Calculation0.
DIST(U1.R00SX,U1.R00SY,
U2.R00SX,U2.R00SY)
Measurement :
Upper
Lower
ENT:Change
Set an expression to find the distance between
two reference position points.
Substituted with calculation 1 and
calculation 0 results
CHECK
2-29-(26)
The settings for the expression are shown in the following diagram.
158.121
:
[
180.000]
:
[
130.000]
Calculation2.
U3.D01-U3.D00
ENT:Change
Finds the difference between calculation 0 and calculation 1.
Expressions are calculated in the order shown in the following diagram.
When using the calculation results from another expression, set the calcula-
tion number to a value larger than the number of the calculation for which the
results are being used. If a smaller number is set, the result of a previous cal-
culation will be inserted instead of the results of the latest calculation.
Calculation1.
DIST(U1.R00X,U1.R00Y,U2.R00X,
U2.R00Y)
Measurement :
158.121
Upper
:
[
Lower
:
[
ENT:Change
Set an expression to find the distance
between two measurement position points.
Calculation order
Calculation 0
Calculation 1
Calculation 7
Section 2-29
180.000]
130.000]

Advertisement

Table of Contents
loading