Omron F250-UME Software Manual page 65

Table of Contents

Advertisement

Basic Operations
HELP
Handling Images for Fine Matching
When Fine Matching is executed, the differential image (where only the differ-
ence between the model and inspection images has been extracted) is stored
as Image 1.
If Image 1 is to be used for measurement for subsequent units, set Change Fil-
tering before the next processing item and obtain the image stored in the
image buffer again.
Camera
setting
Image buffer
Camera
(for Camera 0)
0
Image buffer
Camera
(for Camera 1)
1
Camera
Image buffer
2
(for Camera 2)
Image buffer
Camera
(for Camera 3)
3
Setting Example
0.Scn 0=SET=
0.Camera image
1.Fine matching
2.Change Filtering
3.Binary defect
Image obtained again from image buffer
Fine matching uses Image 0 for
measurement
Filter
0
Camera
selection
Filter
1
The differential image is stored
after fine matching is executed.
Image 1 to be used for
measurement
Section 1-6
Image 0
Image 1
1-(57)