Omron F250-UME Software Manual page 911

Table of Contents

Advertisement

Normal Serial Interface
Data
Settings
177
Inspection
data
region 0
178
179
180
The following settings data is for defect measurement.
Settings
181
Inspection
data
region 0
182
183
184
185
186
The following settings data is for gravity and area and labeling measurement.
Settings
187
Inspection
data
region 0
188
189
190
191
192
193
194
195
196
The following settings are for labeling measurement.
Settings
197
Inspection
data
region 0
198
199
200
201
202
203
204
Details
Region upper left X (0 to 511) (See note.)
Region upper left Y (0 to 483) (See note.)
Region lower right X (0 to 511) (See note.)
Region lower right Y (0 to 483) (See note.)
Extracting level
0: Level 1 1: Level 2 2: Level 3
3: Level 4 4: Level 5
Defect color
0: Black
1: White
Defect width upper limit (0 to 100)
Defect width lower limit (0 to 100)
Defect length upper limit (0 to 999)
Defect length lower limit (0 to 999)
X upper limit (-9,999.999 to 9,999.999)
X lower limit (-9,999.999 to 9,999.999)
Y upper limit (-9,999.999 to 9,999.999)
Y lower limit (-9,999.999 to 9,999.999)
Area upper limit (0.000 to 9,999,999.999)
Area lower limit (0.000 to 9,999,999.999)
Binary level upper limit (0 to 255)
Binary level lower limit (0 to 255)
Reverse binary level
0: Not reversed
1: Reversed
Defect display
0: Simple
1: Detail
No. of labels upper limit (0 to 2,500)
No. of labels lower limit (0 to 2,500)
Noise area upper limit (0 to 9,999,999.999)
Noise area lower limit (0 to 9,999,999.999)
Fill Holes Mode
0: OFF
1: ON
Sort
0: Area descending 1: Area ascending
2: X gravity descending 3: X gravity ascending
4: Y gravity descending 5: Y gravity ascending
Outside trimming
0: OFF
1: ON
No. of labels (0 to 2,499)
Section 6-2
6-2-(61)

Advertisement

Table of Contents
loading