2-23-1
Selecting Measurement Images
CHECK
2-23-(3)
This section describes how to select an image stored at either Image 0 or
Image 1 as the image for measurement.
The edges are extracted for the image number selected here and this image is
then stored at the other image number. Set Change Filtering as the next pro-
cessing item to use this image for measurement for all units after the unit for
which ECM search was set. Then store the image stored in the image buffer to
Image 0 or Image 1.
When Image 0 Is Selected as Measurement Image
Image
0
Edge extraction
Edge-extracted image
Image
stored to Image 1.
1
1.
Select ECM search.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
The initial ECM Search Screen will be displayed.
2.
Select Measurement Image.
The selections will be displayed.
Measurement image
3.
Select which image will be used for measurement, the image stored at Im-
age 0 or the image stored at Image 1.
0.Scn 0=SET=
0.Camera image
1.ECM search
2.Change filtering
3.Binary defect
4.
Image 1 used for measurement.
Image read from image buffer again.
0.Camera image
1.ECM search
2.
Measurement image
Extract edges
Measurement conditions
Model registration
Search coordinate
Search region
Judgement conditions
Detailed conditions
Coordinate mode
Image0
Image1
Section 2-23