Omron F250-UME Software Manual page 390

Table of Contents

Advertisement

EC Positioning
2-16-3
Setting Measurement Regions
Positioning mark
Circular
Box
Other figures
One angle used as a
mark
Several angles are
used to one set of
coordinates
2-16-3-1
Circles
STEP 1: Setting Measurement Conditions
Measurement conditions
Circle color
Skipping
Circular value
Checks circle deformation. (0% to 100% (0%*))
The value drops if the circle is deformed or chipped. The object is not
extracted as a circle if the value is lower than the set value.
The asterisk (*) indicates the default setting.
2-16-(7)
The following four figures can be chosen for measurement regions, depending
on the shape of the positioning mark. Up to 8 regions can be set, and figures
can be selected independently for each region.
Figure
Circle
Box
Cross point
Multiple cross
points
1
2
Set the
Set the
measure-
search
ment condi-
region.
tions.
Set the conditions to search for the positioning mark.
:
Black
:
ON
:
[ 0]%
End
Searches for a circle of a specified size and can out-
put the position coordinates (center of the circle).
Searches for a rectangle of a specified size and can
output the position coordinates. The center or one
of the four corners can be selected for the position
coordinates.
Outputs the position coordinates for the intersection
of two lines.
If there are multiple lines, the following conditions
can be set:
œ
Output the cross point only for intersections at a
certain angle.
œ
Output the cross point only for intersections of
lines of a certain length.
Up to 20 cross point coordinates can be found.
The detection conditions can be changed to suit any
purpose.
3
Register
the size of
the circle.
Select whether the color of the circle that is the
positioning mark will be white or black compared to the
background.
Select "white/black" if circle color not fixed to either
black or white. (Black*, white, white/black)
Select whether pixel skipping (1 pixel) will be used
when searching for the circle. (ON*, OFF)
Processing is faster if pixel skipping is ON so normally it
is appropriate to set pixel skipping to ON. However, if
the measurement values vary, set to OFF.
Section 2-16
Details
(As required)
(As required)
4
5
Register
Set
reference
judgement
position.
conditions.