Omron F250-UME Software Manual page 598

Table of Contents

Advertisement

Labeling
2-25-8
Measurement Screens
SeeAlso
CHECK
2-25-(15)
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for labeling.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which labeling is set and the
following detailed screens will be displayed.
0.Scn 0
RUN
1. Labeling
Judge
: OK
Number of Labels : 3
Area
: 135
Gravity X
: 150.212
Gravity Y
: 250.533
RUN
NG
Image status
:
Freeze(Before scroll)
Display image
:Image0
Image size
:
All
Display results
:
Details
End
Image 0 Freeze
OK 45ms
Judgement result for this Unit
Display is inverted for NG.
The measurement region is displayed
in the OK color for an OK judgement;
in the NG color for an NG judgement.
A circle is displayed at the center
of gravity for an OK judgement; an
ex, for a NG judgement.
Section 2-25
for details on Monitor and
67ms