Omron F250-UME Software Manual page 919

Table of Contents

Advertisement

Normal Serial Interface
CHECK
Edge Position (Settings Data)
Data
Settings
50
Measurement image
data
0: Image 0
1: Image 1
51
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
52
Region 0
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
Region 1
to
157
Region 7
to
171
Only the allocations for region 0 are listed here. Refer to the allocations for
region 0 to calculate the numbers for regions 1 to 7.
Details
Edge detection direction
0:
1:
2:
3:
Edge color
0: Light
dark
1: Dark
light
X upper limit (-9,999.999 to 9,999.999)
X lower limit (-9,999.999 to 9,999.999)
Y upper limit (-9,999.999 to 9,999.999)
Y lower limit (-9,999.999 to 9,999.999)
Edge level (0 to 100)
Noise level (0 to 255)
Noise width (0 to 255)
Region upper left X (0 to 511)
Region upper left Y (0 to 483)
Region lower right X (0 to 511)
Region lower right Y (0 to 483)
Reference position X (0 to 511)
Reference position Y (0 to 483)
Edge detection method
0:
1:
2:
3:
... (Same as for region 0)
Edge detection method
0:
1:
2:
3:
... (Same as for region 0)
Reference position Y (0 to 483)
Section 6-2
6-2-(69)