Omron F250-UME Software Manual page 596

Table of Contents

Advertisement

Labeling
2-25-6
Setting Judgement Conditions
Judgement conditions
Number of labels : 8 [
Judge area
[
0.000 :
Gravity X
[
0.000 :
511.000]
Gravity Y
[
0.000 :
483.000]
End
: Measurement results for the displayed image.
Use these values as references for setting upper and lower limits.
2-25-(13)
Set the ranges for the number of labels, area and center of gravity for an OK
judgement.
Ranges for an OK judgement
Range for number of labels in measurement region (0 to 2,500)
0: 2500]
Range for specified label number area (0 to 9,999,999.999)
:
2035.000
247808.000
]
: 26.000
Range of movement in X direction for
:157.000
specified label number (-9,999.999 to 9,999.999)
Range of movement in Y direction for
specified label number (-9,999.999 to 9,999.999)
1.
Select Judgement conditions.
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Measurement image
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Coordinate mode
Number of labels : 8 [
Judge area
: 2035.000
[
2000.000 :
2300.000
Gravity X
: 26.000
[
0.000 :
511.000]
Gravity Y
:157.000
[
0.000 :
483.000]
End
Section 2-25
0: 2500]
]

Advertisement

Table of Contents
loading

Table of Contents