EC Defect
STEP 1: Setting Binary Levels
SeeAlso
SeeAlso
STEP 2: Setting Measurement Conditions
2-15-(41)
Adjust the binary levels so that the area to be measured appears as white pix-
els.
1.
Display the measurement method selections using the same steps 1 to 3
as outlined under Defect.
Refer to page 2-15-(32).
New registration(Inspected R0)
2.
Select Gravity and area.
The initial Gravity and Area Screen will be displayed.
3.
Select Binary.
The rest of the procedure is the same as for labeling.
Refer to page 2-15-(35).
Set the measurement conditions if using fill profile or defect display functions.
Fill Profile
Turn ON the fill profile function to measure the whole area between the start
point (black pixels to white) and the end point (white pixels to black) in the
measurement region as white pixels. The default setting is OFF.
This area will be measured as white pixels.
Defect
Labeling
Gravity and area
Binary
Measurement conditions
Inspected region
Judgement conditions
Detailed conditions
Clear
Measurement region
Start point End point
Section 2-15