Omron F250-UME Software Manual page 915

Table of Contents

Advertisement

Normal Serial Interface
EC Positioning (Settings Data)
Data
500
Measurement image
0: Image 0
1: Image 1
501
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
502
Edge extraction mask size
0: 3
3
1: 5
5
503
Edge extraction lower limit (10 to 255)
504
Edge extraction upper limit (10 to 255)
505
Region 0
506
507
508
509
510
511
The following settings data is for circle measurement.
Settings
512
Region 0
data
513
514
515
516
517
518
519
520
Details
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to483)
Reference position X (0 to 511)
Reference position Y (0 to 483)
Reference angle (0 to 359)
Circle color
0: Black
1: White
2: Both
Skipping
0: OFF
1: ON
Circular value (0 to 100)
Center X (0 to 511)
Center Y (0 to 483)
Circumference radius (3 to 512)
Circumference width (1 to 64)
Radius judgement upper limit (1 to 9,999.999)
Radius judgement lower limit (1 to 9,999.999)