Classification
CHECK
Rough Search
Searches all of the measurement
region using a rough search model.
Search
Rough search model
Interpolation Mode
HELP
Note Indicates the number of models when interpolation mode is set to ON.
The Controller performs the following 2-stage processing internally.
When 2 or more models are registered to in the same index, set whether or
not to search using an auxiliary model.
Selection
ON*
The registered models and auxiliary models will be used in
searches. The measurement will be more stable. Processing time,
however, will be longer.
OFF
The searches will be performed with registered models only.
The asterisk (*) indicates the default setting.
Auxiliary model
Auxiliary models are models created between the registered models.
Auxiliary models are automatically created by the Controller when multiple
models have been registered to the same index number.
Number of
registered models
auxiliary models
2
1
3
3
4
6
5
10
Detailed Search
Measures again using the detailed search model to
compare to the images surrounding the section with
the highest correlation.
Search
Detailed search model
Meaning
Number of
Total number of
models (See note.)
3
6
10
15
Section 2-13
Section with the highest
correlation
2-13-(12)