Trend Monitor
2-34-2
Setting Warning Ranges and Judgement Conditions
CHECK
SeeAlso
CHECK
Parameter
Set the judgement conditions for determining if a measurement result will be
OK or NG and set the warning range to encourage caution before too many
NG results are obtained. There are two setting methods: Parameter and
Graph.
Upper judgement limit
Warning range (upper limit)
Warning range (lower limit)
Lower judgement limit
A warning count can be specified to set the number of times the measurement
value must consecutively enter the warning range before a warning is gener-
ated.
Refer to page 2-34-(14).
When a warning is generated, the word Warning appears on the screen.
If an expression is set to output the Trend Monitor measurement result (warn-
ing) using DO Judgement Output or other results output processing items, an
external device can be notified that a warning was generated.
Use parameters to set the upper and lower judgement limits and the warning
range.
Judgement conditions(Parameter)
Limits of judgement :
[
346.500:
Limits of warning
[
365.750:
1.
Select Judgement conditions.
3.Trend monitor
Judgement conditions(Graph)
423.500]
:
404.250]
End
Measurement
Judgement conditions
Display range
Detailed conditions
NG display
Save data
Section 2-34
NG
NG
Lower judgement limit
Upper judgement limit
Warning range (upper limit)
Warning range (lower limit)
Warning
Warning
2-34-(5)