Elapsed Time - Omron F250-UME Software Manual

Table of Contents

Advertisement

Elapsed Time

2-30
Elapsed Time
2-30-(1)
The Elapsed Time processing item finds the amount of time (in ms) that has
passed since the measurement trigger was input.
All that is necessary is to set the Time processing item for a unit. No other set-
tings are required.
The processing time can then be calculated by setting the Elapsed Time pro-
cessing item for units before and after other units, and then using the Calcula-
tion processing item to find the time.
Example 1: Finding the Processing Time for A Particular Unit
1.
Elapsed Time
2.
EC defect
3.
Elapsed Time
4.
Calculation
Example 2: Stopping Measurement if Processing Time Exceeds Set Time
The settings are combined with conditional branching.
4.
EC defect
5.
DO judgement
6.
End
If an expression to find [3.Elapsed Time]
Time] is set, the processing time between units 2 and 3
can be found.
1.
Model position
compensation
2.
Elapsed Time
3.
Branching condition:
Branch
Time
Time
7.
End
Section 2-30
-