Omron F250-UME Software Manual page 502

Table of Contents

Advertisement

QUEST Character Verification
2-21-8
Measurement Screens
SeeAlso
CHECK
Measurement Regions
2-21-(33)
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for QUEST
character verification.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which QUEST character
verification is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the three
screens.
The judgement result for this unit, the set regions, and the extraction frame for
each character will be displayed.
0.Scn 0
RUN
1.QUEST OCV
Judge : OK
0
KB - 6 5 7 6 2
0 1 . 1 1. 0 7
Region number
RUN
NG
Image status
:
Freeze(Before scroll)
Display image
:Image0
Image size
:
All
Display results
:
Details
End
Image 0 Freeze
OK 45ms
47 ms
Judgement result for this unit
Region
The extraction frames will be displayed in
dotted lines for automatic extraction
mode.
Section 2-21
for details on Monitor and
67ms

Advertisement

Table of Contents
loading

Table of Contents