5.16 Allocating Another Output to PASS Output

f
pass
L
(PASS)
0
L
Displays "L 0."
amov
0
L
0
amov
0
L
00000
init
f
L
off
Displays "L f."
pass
f
L
pass
pass
f
L
pass
The "PASS output change" parameter can be set to output a
comparative output or error output from the PASS output terminal
instead of outputting the PASS output. This function is valid only when
there is a PASS output terminal.
In the default settings, PASS signals are output from the PASS output
terminal.
Parameter
PASS output change
pass
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the M [MODE] Key several times to change the PV display
M
to "amov."
• This parameter is not displayed for the initial status due to setting
level protect.
Refer to "5.34 Limiting Key Operations" (P.5-84) for information on
removing setting level protect.
C Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
D Use the U [UP] and S [SHIFT] Keys to set the password "-
U
0169." Press the M [MODE] Key to move to the advanced
function setting level.
M
f" is displayed on the level/bank display to indicate the
• "
L
advanced function setting level.
E Press the M [MODE] Key to change the PV display to "pass."
M
F Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
5.16 Allocating Another Output to PASS Output
Advanced function setting level
Set value
Meaning of set value
ll
l
pass
h
hh
R
P
LL
L
PASS
H
HH
5-51