set sync source

Use the set sync source command to specify which clock source is the active clock source.
The identity of the current synchronization source is not stored in persistent storage.
Syntax
set sync source {primary | secondary | local}
Parameters
Parameter
primary
secondary
local
User level
read-write
Context
general
Example
To set the primary clock as the clock source:
G350-001(super)# set sync source primary
If the secondary interface is not configured, the sync source set operation will fail.
G350-001(super)# set sync source secondary
Operation Failed
Cannot set the secondary clock source to be the active clock source
Related commands
clear sync
interface,
Description
Keyword specifying to set the primary clock
source to be active
Keyword specifying to set the secondary
clock source to be active, and the primary
clock source on standby
Keyword specifying to set the local clock to
be active
set sync
interface,
set sync
Alphabetical listing of CLI commands
Possible
Values
switching,
show sync timing
Default
Value