Example
To create a new channel group number 2, with time slots 5, 6, and 8 and speed of 56:
G350-001(controller:5/1)# channel-group 2 timeslots 5-6,8 speed 56
Related commands
cablelength
long,
ip
address,
linecode
cir out
Use the cir out command to configure the Committed Information Rate in bits per second,
for the outbound direction. Use the no form of this command to return the CIR to its default
value.
Note:
This command fails if the map class is currently associated with a DLCI.
Note:
Syntax
cir out cir
no cir out
Parameters
Parameter
cir
User level
read-only
Context
map-class frame-relay
Example
To configure outbound CIR to be 64 Kbps:
G350-001(map-class)# cir out 64000
Related commands
bc
out,
be
out,
cablelength
short,
clock
(E1),
linecode
(T1), remote,
Description
The CIR in bits per second
de
pre-mark,
de-buffer-size
Alphabetical listing of CLI commands
source, controller, ds-mode, framing,
show controllers
Possible Values
0-39999999
interface
serial,
Default Value
56000
Issue 1.1 June 2005