CLI Commands
User level
read-write
Context
cna-testplug
Example
To set the CNA test rate limit to 70 tests every 20 seconds:
G350-001(cna-testplug 1)#
Related commands
clear counters (CNA test
rtp-test-port, scheduler,

threshold count

Use the threshold count command to specify the upper and lower thresholds for the
threshold in the track list command. Use the no form of this command to restore the
default values.
Syntax
[no] threshold count [up up_number] [down down_number]
Parameters
Parameter
up_number
down_number
User level
read-write
Context
track list
772 Avaya G250 and Avaya G350 CLI Reference
test-rate-limit 70 20
plugs), cna-testplug, cna-testplug-service, control-port, rtp-echo-port,
show cna
testplug,
shutdown (CNA test plugs)
Description
The upper threshold for the threshold count
in the track list command
The lower threshold for the threshold count
in the track list command
Possible
Default
Values
Value
1-50
1
1-50
0