set port auto-negotiation-flowcontrol-advertisement

Use the set port auto-negotiation-flowcontrol-advertisement command to set
the flowcontrol advertisement for the specified port when performing autonegotiation.
Syntax
set port auto-negotiation-flowcontrol-advertisement module/port
{no-flowcontrol|asym-tx-only|sym-only|sym-and-asym-rx}
Parameters
Parameter
module
port
no-flowcontrol
asym-tx-only
sym-only
sym-and-asym-rx
User level
read-write
Context
general
Example
To specify that port 5 of module 2 will advertise asymmetric Tx pause capabilities only:
G350-001(super)# set port auto-negotiation-flowcontrol-advertisement
2/5 asym-tx-only
Port 2/5 pause capabilities was set
Description
Number of the module
Number of the port on the module.
You can also specify a range of ports
separated by a dash, for example, 4/5-13
for ports 5 to 13 on module 4.
The port will advertise no pause
capabilities.
The port will advertise asymmetric Tx
pause capabilities only.
The port will advertise symmetric pause
capabilities only.
The port will advertise both symmetric and
asymmetric Rx pause capabilities.
Alphabetical listing of CLI commands
Possible
Values
Issue 1.1 June 2005