CLI Commands
Syntax
[no] client-identifier unique-identifier
Parameters
Parameter
unique-
identifier
User level
read-write
Context
dhcp pool
Example
To set the MAC address as a client identifier for an Ethernet MAC client with MAC address
00:11:22:33:44:55:
G350-001(DHCP 5)# client-identifier 01:00:11:22:33:44:55
Related commands
bootfile, default-router, dns-server, domain-name, end-ip-addr, lease, name, next-server,
option, server-name,
vendor-specific-option

clock source

Use the clock source command to configure the clock source for an E1/T1 controller. Use
the no form of the command to return the clock source to the default value of line.
Syntax
clock source {line | internal}
no clock source
96 Avaya G250 and Avaya G350 CLI Reference
Description
A unique identifier for
a DHCP client, in the
format type:data
show ip
dhcp-pool, start-ip-addr, subnet-mask, value,
Possible Values
Hex string, any value.
For Ethernet MAC use
<type>:<data> format,
where <type> is 01 and
<data> is the MAC
address of the device.
Default Value
null hex string