track

Use the track command to configure an object tracker. Use the no form of this command to
delete the object tracker.
You can configure two types of object trackers:
An object tracker which tracks the state of a single RTR object.
A track list which is composed of multiple previously-defined object trackers. Note that
when configuring a track list you may also specify how to calculate the state of the list
based on the states of the individual object trackers composing the list. If you do not
specify how to calculate the state of the list, the boolean AND argument is used.
Note:
You cannot delete an object tracker which is a member of a track list. You must
Note:
first remove the object tracker from the track list using the no object command.
You cannot delete an object tracker which was linked to an application using the
keepalive-track command. You must first use the no keepalive-track
command to disable the link.
Syntax
[no] track track-id rtr rtr-id
[no] track track-id
Parameters
Parameter
track-id
rtr-id
boolean
and
list [{boolean {and | or} | threshold count}]
Description
The track list ID.
The RTR operation ID.
Keyword specifying that the state of the
tracked list is based on a Boolean
calculation.
Specifies that the list is up if all objects are
up, or down if one or more of the objects are
down. For example, when tracking two
interfaces, up means that both interfaces are
up, and down means that either interface is
down.
Alphabetical listing of CLI commands
Possible
Values
1-50
1-30
Issue 1.1 June 2005
Default
Value