path ds1|e1 bert

Syntax
Release Information
Description
Options
Mode
134
path pathChannel { ds1 | e1 } tributaryIdentifier bert
pattern pattern interval time [ unframed ]
no path pathChannel { ds1 | e1 } tributaryIdentifier bert
Command introduced before JunosE Release 7.1.0.
Enables bit error rate tests using the specified pattern at the DS1/E1 over SONET/SDH
VT layer on channelized SONET and SDH interfaces. The no version stops the test that
is running.
pathChannel—Number, in the range 1–2147483648, that identifies the path
tributaryIdentifier—Specifier for the tributary in the format
pathChannel { ds1 | e1 } pathPayload/tributaryGroup/tributaryNumber
pathPayload—Payload number for the path; value is 1 for SONET and in the range
1–3 for SDH
tributaryGroup—Number, in the range 1–7, that identifies the group within the path
tributaryNumber—Number of the tributary within the tributary group; the value is in
the range 1–4 if the tributary type is vt15 or tu11 and in the range 1–3 if the tributary
type is tu12
pattern—One of the following test patterns:
2^11—Pseudorandom test pattern, 2,047 bits long
2^15—Pseudorandom test pattern, 32,767 bits long
2^20-O153—Pseudorandom test pattern, 1,048,575 bits long
time—Duration of the test, in the range 1–1440 minutes
unframed—Test bit pattern occupies all bits on the link, overwriting the framing bits.
If you do not specify this keyword, the test bit pattern occupies only T1/E1 payload bits.