JunosE 11.3.x Command Reference Guide N to Z
resource if-type
Syntax
Release Information
Description
Options
Mode
392
[ no ] resource if-type { atm-active-sub-if | atm-sub-if | atm-vc | ip | ppp-link }
{ slot slot | system }
threshold { falling fallingValue | hold-down-time holdDownTime | rising
risingValue }
Command introduced before JunosE Release 7.1.0.
Specifies threshold values for specific interface types on a slot or systemwide basis. The
no version sets the threshold parameter to its default value (for rising, 90% of the
maximum value of the resource; for falling, 1% of the maximum value of the resource;
for hold-down time, 300 seconds).
CAUTION: Do not specify a falling value larger than the specified rising value;
do not specify a rising value smaller than the specified falling value.
atm-active-sub-if—Configures active ATM subinterfaces
atm-sub-if—Configures both active and inactive ATM subinterfaces
atm-vc—Configures ATM virtual circuits
ip—Configures IP interfaces
ppp-link—Configures PPP link interfaces
slot—Number of the chassis slot in the range 0–2 (ERX310 model), 0–6 (ERX7xx
models), 0–13 (ERX14xx models), 0–5 (E120 router), and 0-16 (E320 router)
For ERX7xx models, a number in the range 0–6; for ERX14xx models, a number in the
range 0–13; for the ERX310 router, a number in the range 1–2; for the E120 router, a
number in the range 0–5; for the E320 router, a number in the range 0–16
fallingValue—Falling threshold for the resource, in the range 0–4294967295
holdDownTime—Hold-down time for the resource, in the range 0–4294967295 seconds
risingValue—Rising threshold for the resource, in the range 0–4294967295
Global Configuration
Copyright © 2010, Juniper Networks, Inc.