Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE N TO Z 2010-10-19 Command Reference Manual page 52

Software for e series broadband services routers command reference n to z
Table of Contents

Advertisement

JunosE 11.3.x Command Reference Guide N to Z
10
Table 3: Interface Types and Specifiers for ERX7xx Models, ERX14xx
Models, and ERX310 Router (continued)
Interface Type
Description
CT3
E3/T3 Frame
cOCx/STMx:
unframed E1
Interface Specifier
slot/port:channel/subchannel[.subinterface ]
slot—Number of the chassis slot in the range
0–6 (ERX7xx models) and 0–13 (ERX14xx
models)
port—Port number on the I/O module
channel—Number of a T1 channel on a CT3
module; in the range 1–28
subchannel—Number of the channel group
associated with a range of DS0 timeslots
on a CT3 module; in the range 1–28
subinterface—Number of the subinterface
in the range 1–2147483647
slot/port[.subinterface ]
slot—Number of the chassis slot in the range
0–6 (ERX7xx models) and 0–13 (ERX14xx
models)
port—Port number on the I/O module
subinterface—Number of the subinterface
in the range 1–2147483647
slot/port:path-channel/path-payload/
tributary-group/tributary-number/
channelNumber[.subinterface ]
slot—Number of the chassis slot in the range
0–6 (ERX7xx models), 0–13 (ERX14xx
models), and 0–2 (ERX310 router)
port—Port number on the I/O module
path-channel—Number of the STS-1or
STM-0 line in the range 1–2147483648
path-payload—Number of the payload
within the path
tributary-group—Number of the tributary
group within the path
tributary-number—Number of the tributary
within the group
channelNumber—1 (the router assigns the
number one to an unframed E1 channel)
subinterface—Number of the subinterface
in the range 1–2147483647
Copyright © 2010, Juniper Networks, Inc.
Example
serial 3/2:20/15