JunosE 11.3.x Command Reference Guide N to Z

rtr reaction-configuration test-failure

Syntax
Release Information
Description
Options
Mode
420
rtr reaction-configuration rtrIndex test-failure [ testFailureValue ]
Command introduced before JunosE Release 7.1.0.
Enables test failure reaction to occur. When the type of RTR entry is echo, you can also
configure a value that triggers the test-failure trap. There is no no version. See the no rtr
reaction-configuration command.
rtrIndex—Number of the operation to be configured, in the range 1–4294967295; no
default
testFailureValue—Number, in the range 0–15; default value is 1