Rtr Schedule Life - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE N TO Z 2010-10-19 Command Reference Manual

Software for e series broadband services routers command reference n to z
Table of Contents

Advertisement

rtr schedule life

Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
rtr schedule rtrIndex life lifeValue
Command introduced before JunosE Release 7.1.0.
Specifies the length of the RTR probe. There is no no version.
rtrIndex—Number of the operation to be configured, in the range 1–4294967295; no
default
lifeValue—Number of operations or maximum TTL in the range 1–2147483647; value
that depends on the type of the RTR entry
If the type of the RTR entry is echo, lifeValue relates to the number of operations
sent until a test finishes. The default value is 90. If you use 60 operations * 60
seconds, the frequency between each operation that a test completes is 3,600
seconds (one hour).
If the type of the RTR entry is pathEcho, lifeValue relates to the maximum number
of hops used by the traceRoute trap. The default value is 30. If you use 30 (as the
maximum hops) * 3 (operations per hop) * 60 seconds frequency between each
operation, a test is completed within 3,600 seconds. If a destination is reached in
fewer than 30 hops, the test is completed earlier.
Global Configuration
Chapter 6: R Commands
423

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.3

Table of Contents