Off-Premises Or Out-Of-Building Stations; Task List: Off-Premises Requirements; Off-Premises Connections - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Install and Wire Telephones

Off-Premises or Out-of-Building Stations

3
Connect an A25D cable between the sneak fuse panel and the terminal block connector associated
with the green row in the previous step.
4
Install a green label on the terminal block to identify the remote location.
5
Administer using the Administrator's Guide for Avaya Communication Manager (555-233-506).
Return to Task List
Off-Premises or Out-of-Building Stations
Return to Task List
Out-of-building campus stations are telephones/voice terminals not physically located in the same
building as the equipment room but located on the same property. Only analog telephones connected to
TN742, TN746B, TN2183, or TN769 Analog Line circuit packs can be installed out-of-building.

Task List: Off-Premises Requirements

Off-Premises Connections

Off-Premises Protection Requirements
Voice Terminal Restrictions for Exposed Environments
Digital Out-of-Building Voice Terminal Protection
Off-Premises Connections
Return to Task List
Figure 203, Connections for 1 to 8 Out-of-Building Analog Telephones,
connections for 1 to 8 off-premises analog telephones.
Figure 204, Connections to 24 Out-of-Building Telephones,
24 off-premises analog telephones. Concentrations of analog line pairs are used at both buildings to
minimize the off-premises wiring required. At the MDF, jumpers must be connected between 1
row/connecting block in the white field and up to 3 rows/connecting blocks in the purple field. At the
station location, a WP-90929, List 1 Concentrator Cable is used. There are 8 station appearances on each
of the 3 fingers of the concentrator cable.
The maximum distance from the system cabinet to the out-of-building voice terminal is 6000 feet (1828.8
meters) using 24 AWG (#5) (0.5 mm
The maximum range of out-of-building analog telephones (500-, 2500-, or 7100-types) connected to an
analog line circuit pack should be such that the maximum loop resistance does not exceed 1300 ohms.
526
on page 526
on page 528
on page 529
on page 528 shows the connections for up to
2
) wire.
on page 529
on page 527 shows the
SI Installation and Upgrades
June 2004