rtr schedule life
rtr schedule rtrIndex life lifeValue
Syntax
Command introduced before JUNOSe Release 7.1.0.
Release Information
Specifies the length of the RTR probe. There is no no version.
Description
Options
Global Configuration
Mode
rtrIndex Number of the operation to be configured, in the range 1–4294967295;
no default
lifeValue Number of operations or maximum TTL in the range 1–2147483647;
value that depends on the type of the RTR entry
If the type of the RTR entry is echo, lifeValue relates to the number of
operations sent until a test finishes. The default value is 90. If you use 60
operations * 60 seconds, the frequency between each operation that a test
completes is 3,600 seconds (one hour).
If the type of the RTR entry is pathEcho, lifeValue relates to the maximum
number of hops used by the traceRoute trap. The default value is 30. If you
use 30 (as the maximum hops) * 3 (operations per hop) * 60 seconds
frequency between each operation, a test is completed within 3,600 seconds.
If a destination is reached in fewer than 30 hops, the test is completed earlier.
Chapter 6: R Commands