DPNSS/DASS configuration - DDSL data blocks
Configuring DPNSS/DASS D-channel interface using LD 74
configuration required for the DDSL data blocks used for DPNSS protocols.
Configuring DPNSS/DASS D-channel interface using LD 74
1. Log on to the CS 1000E.
2. To access LD 74, enter:
3. Enter the responses shown in
Configure CE-MUX clock controllers
You must configure the CE-MUX clock controllers as well as error detection thresholds in PRI
Gateway.
These prompts are enabled when the IPMG package (package number 403) is enabled,
regardless of the state of the softswitch package.
Media Gateway 1000E PRI Gateway Installation and Commissioning
LD 74
configuration (LD 74)
Table 23: DPNSS/DASS D-channel interface configuration (LD 74)
Prompt
Response
REQ
NEW
TYPE
DDSL
S2
0
DDSL
0 - 15
SIGL
DA
DDCS
0 - 254
PRIV
YES/NO
SIDE
AET/BNT
...
...
Table 23: DPNSS/DASS D-channel interface
on page 91.
New data.
Digital Signaling Link.
DCHI switch setting (the normal addressing
mode for MGP).
The D-channel logical port number, entered in
LD 17.
DPNSS1/DASS2 digital signaling.
Loop number used for the PRI link (reference to
DDCS in LD 17).
YES = Private DPNSS1 link.
NO = DASS2 link.
The AET/BNT end of DPNSS1 link.
Configure E1/T1 ports on a Call Server
on page 91 describes the
Description
March 2013
91