2272
C
149: NQA C
HAPTER
Parameter
Description
Example
history-records
Syntax
View
Parameter
Description
Example
C
C
LIENT
ONFIGURATION
OMMANDS
interval: Interval between two consecutive tests, in milliseconds, in the range 0 to
604800000. If the interval is 0, it indicates that only one test is performed.
Use the
frequency
tests for a test group.
Use the
undo frequency
By default, the interval between two consecutive tests for a test group is 0
milliseconds, that is, only one test is performed.
After you use the nqa schedule command to start an NQA test, one test is started
at interval.
n
If the last test is not completed when the interval specified by the frequency
command is reached, a new test is not started.
# Configure the interval between two consecutive tests as 1000 milliseconds.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] frequency 1000
history-records number
undo history-records
Any NQA test type view
number: Maximum number of history records that can be saved in a test group, in
the range 0 to 50.
Use the
history-records
records that can be saved in a test group.
Use the
undo history-records
By default, the maximum number of records that can be saved in a test group is
50.
If the number of history records exceeds the maximum number, the earliest history
record for a probe will be discarded.
# Configure the maximum number of history records that can be saved in a test
group as 10.
<Sysname> system-view
[Sysname] nqa entry admin test
command to configure the interval between two consecutive
command to restore the default.
command to configure the maximum number of history
command to restore the default.