Display Rmon Prialarm - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

display rmon prialarm

Syntax
View
Parameter
Description
Related command:
Example
Table 611 Description on the fields of the display rmon history command
Field
utilization
display rmon prialarm [ entry-number ]
Any view
entry-number: Private alarm entry index, in the range 1 to 65535. If no entry is
specified, the configuration of all private alarm entries is displayed.
Use the
display rmon prialarm
specified or all private alarm entries.
rmon prialarm.
# Display the configuration of all private alarm entries.
<Sysname> display rmon prialarm
Prialarm table 5 owned by user1 is UNDERCREATION.
Samples type
Variable formula
.16.1.1.1.6.1)*100/.1.3.6.1.2.1.16.1.1.1.5.1)
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever
Latest value
Table 612 Description on the fields of the display rmon prialarm command
Field
Prialarm table
owned by
VALID
Samples type
Variable formula
Sampling interval
Rising threshold
Falling threshold
linked with event
Description
Bandwidth utilization during the sampling period
command to display the configuration of the
: changeratio
: ((.1.3.6.1.2.1.16.1.1.1.5.1-.1.3.6.1.2.1
: ifUtilization.GigabitEthernet1/0
: 10(sec)
: 892340484(linked with event 1)
: 889783312(linked with event 2)
: risingOrFallingAlarm
: 0
Description
Index of the prialarm table
Owner of the entry, user1 in this example
Status of the entry identified by the index (VALID means the entry is
valid, and UNDERCREATION means invalid. You can use the display
rmon command to view the invalid entry and with the display
current-configuration and display this commands you cannot
view the corresponding rmon commands.)
Samples type
Variable formula
Sampling interval
Alarm rising threshold. An alarm event is triggered when the
sampled value is greater than or equal to this threshold.
Alarm falling threshold. An alarm event is triggered when the
sampled value is less than or equal to this threshold.
Event index associated with the prialarm
2319

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all

Table of Contents