Ethernet OAM Commands
ethoam fault-reset-time
Configures the timer value for the Fault Notification Generation Reset time that specifies the time interval
during which the fault alarm is re-enabled to process faults. The fault alarm will only be re-enabled if no
new faults are received during this time interval.
ethoam fault-reset-time centiseconds endpoint endpoint_id domain {mac_add | d-name} association a-
name
no ethoam fault-reset-time endpoint endpoint_id domain {mac_add | d-name} association a-name
Syntax Definitions
centiseconds
mep-id
d-name
a-name
Defaults
parameter
centiseconds
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
•
Use the no form of this command to restore the Fault Notification Generation Reset timeout value to
the default value.
•
The Fault Notification Generation Reset timer value is configurable per MEP.
Examples
-> ethoam fault-reset-time 250 end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
-> no ethoam fault-reset-time end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
Release History
Release 6.3.1; command was introduced.
OmniSwitch CLI Reference Guide
The Fault Notification Generation Reset timer value, in centi seconds.
The valid range is 250–1000.
Specifies the MEP of a specific MA. The valid range is 1–8191.
Specifies the domain name. For more information on the different
formats of the domain name, refer to
page
45-3.
Name of the Ethernet OAM Association. Up to 48 (minus the domain
name length) characters may be used.
default
1000
June 2012
ethoam vlan command on
page 45-43