Ethernet OAM Commands

ethoam fault-reset-time

Configures the timer value for the Fault Notification Generation Reset time that specifies the time interval
during which the fault alarm is re-enabled to process faults. The fault alarm will only be re-enabled if no
new faults are received during this time interval.
ethoam fault-reset-time centiseconds endpoint endpoint_id domain {mac_add | d-name} association a-
name
no ethoam fault-reset-time endpoint endpoint_id domain {mac_add | d-name} association a-name
Syntax Definitions
centiseconds
mep-id
d-name
a-name
Defaults
parameter
centiseconds
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
Use the no form of this command to restore the Fault Notification Generation Reset timeout value to
the default value.
The Fault Notification Generation Reset timer value is configurable per MEP.
Examples
-> ethoam fault-reset-time 250 end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
-> no ethoam fault-reset-time end-point 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
Release History
Release 6.3.1; command was introduced.
OmniSwitch CLI Reference Guide
The Fault Notification Generation Reset timer value, in centi seconds.
The valid range is 250–1000.
Specifies the MEP of a specific MA. The valid range is 1–8191.
Specifies the domain name. For more information on the different
formats of the domain name, refer to
page
45-3.
Name of the Ethernet OAM Association. Up to 48 (minus the domain
name length) characters may be used.
default
1000
June 2012
ethoam vlan command on
page 45-43