Chassis Management and Monitoring Commands
output definitions
Hardware Board
Temperature
Temperature Upper
Threshold Range
Temperature Upper
Threshold
Temperature Status
Temperature Danger
Threshold
Release History
Release 6.1; command was introduced.
Related Commands
temp-threshold
show fan
MIB Objects
chasChassisTable
chasHardwareBoardTemp
chasTempRange
chasTempThreshold
chasDangerTempThreshold
OmniSwitch CLI Reference Guide
The current chassis temperature as determined by the built-in tempera-
ture sensor. The temperature is displayed in degrees Celsius. This tem-
perature is checked against the upper threshold value. If the threshold is
exceeded, a warning is sent to the user.
The supported threshold range when specifying a threshold for the
switch via the
temp-threshold
The warning temperature threshold, in degrees Celsius. If the switch
reaches or exceeds this temperature, the primary switch or CMM's
TEMP LED displays amber and a warning is sent to the user. For infor-
mation on changing the upper threshold value, refer to the
threshold command on page
The current threshold status of the switch. Displays whether the switch
is UNDER THRESHOLD or OVER THRESHOLD. If the status is
OVER THRESHOLD, the primary CMM's TEMP LED displays
amber and a warning is sent to the user.
The factory-defined danger threshold. This field is not configurable. If
the chassis temperature reaches this value the switch will power off all
Network Interface (NI) modules until the temperature conditions (e.g.,
chassis air flow obstruction or ambient room temperature) have been
addressed.