aaa hic redundancy background-poll-interval
Configures the background polling interval that determines when the primary server is considered active
after being inactive.
aaa hic redundancy background-poll-interval value
Syntax Definitions
value
Defaults
parameter
value
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855
Usage Guidelines
•
If the primary server is unavailable and placed in the inactive mode the switch begins to poll the
primary server in the background.
•
In order to avoid overwhelming a primary server that becomes active again the switch will generate a
random reconnect value. When the switch receives continuous keepalive responses equal to the random
reconnect value it assumes the primary server is ready to takeover the active role.
•
When the backup server is inactive this interval determines the frequncy at which the poll packets
should be sent to backup server.
•
Once the primary server becomes active, the backup server becomes inactive.
Examples
-> aaa hic redundancy background-poll-interval 32
Release History
Release 6.4.4; command was introduced.
page 36-90
The background polling interval in seconds. The valid range is from 16
to 256 in multiples of 16.
default
16
OmniSwitch CLI Reference Guide
AAA Commands
June 2012