Copy Flash-Synchro - Alcatel-Lucent OmniSwitch 6850-48 Cli Reference Manual

Alcatel-lucent omniswitch 6850-48: reference guide
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

CMM Commands

copy flash-synchro

Copies the certified directory version of the primary CMM software to the certified directory of the
secondary CMM.
[configure] copy flash-synchro
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
This command is used to synchronize the certified directories of the primary and secondary CMMs.
The two CMMs must be in synchronization if a fail over occurs, otherwise switch performance is lost.
If the switch is part of a stack, all switches in the stack are updated with the primary CMM files.
Examples
-> copy flash-synchro
-> configure copy flash-synchro
Release History
Release 6.1; command was introduced.
Related Commands
copy working certified
MIB Objects
chasControlModuleTable
csEntPhysicalIndex
chasControlVersionMngt
OmniSwitch CLI Reference Guide
Copies the working primary flash version of the CMM software to cer-
tified primary flash. Or copies the working primary flash version of the
CMM software to startup secondary flash.
June 2012
page 53-15