Ethernet OAM Commands
output definitions
Admin State
Direction
Slot/Port
MAC Address
Fault Notification
RFP Status
CCM Enabled
CCM Linktrace Priority
CCM Not Received
CCM Error defect
CCM Xcon defect
MEP RDI Received
MEP Last CCM Fault
MEP Xcon Last CCM Fault
MEP Error Mac Status
MEP Lbm NextSeqNumber
MEP Ltm NextSeqNumber
Fault Alarm Time
Fault Reset Time
Lowest PrDefect Allowed
Highest PrDefect Present
Release History
Release 6.2.1; command was introduced.
Release 6.3.4; mac_address parameter deleted.
Release 6.4.4; RFP Status added.
OmniSwitch CLI Reference Guide
Indicates the administrative state (up or down) of the MEP.
The direction of the MEP.
The slot/port number of the Bridge port to which the MEP is attached.If
the value is virtual, it indicates a virtual port.
The MAC address of the MEP.
Indicates the current state of the MEP Fault Notification
Generator State Machine, which can be FNG_RESET,
FNG_DEFECT, FNG_REPORT_DEFECT,
FNG_DEFECT_REPORTED, or FNG_DEFECT_CLEARING.
Indicates the status of the RFP.
Indicates whether the MEP generates CCMs (enabled) or not (dis-
abled).
Indicates the priority value for CCMs and LTMs transmitted by the
MEP.
Indicates if CCMs are not being received (true) or received (false)
from at least one of the configured remote MEPs.
Indicates if a stream of erroneous CCMs is being received (true) or not
(false) from a MEP in this MA.
Indicates if a stream of CCMs is being received (true) or not (false)
from a MEP that belongs to another MA.
Indicates that any other MEP in this MA is transmitting the RDI bit.
Options include true or false.
The last-received CCM that triggered a MA fault.
The last-received CCM that triggered a cross-connect fault.
Indicates a port status TLV. Options include true or false.
The next Transaction Identifier or Sequence Number to be sent
in an LBM.
The next Transaction Identifier or Sequence Number to be sent
in an LTM.
The time interval during which one or more defects should be detected
before the fault alarm is issued
The time interval during which the fault alarm is re-enabled to process
faults
The lowest priority defect that allowed to generate fault alarm.
The highest priority defect since the MEPs Fault Notification Generator
in reset state.