Chassis Management and Monitoring Commands
output definitions (continued)
Operational Status
Power Consumption
Power Control Checksum
MAC Address
ASIC - Physical
CPLD - Physical
UBOOT Version
UBOOT-miniboot Version
POE SW Version
C20L Upgd FailCount
Release History
Release 6.1; command was introduced.
Release 6.1.5; fields added.
Related Commands
reload ni
power ni
show module
show module long
show module status
MIB Objects
chasEntPhysOperStatus
OmniSwitch CLI Reference Guide
The operational status of the NI. Options include UP or DOWN. The
operational status can be DOWN while the power status is on, indicat-
ing a possible software issue.
The current power consumption for the CMM.
The current power control checksum for the corresponding NI.
The MAC address assigned to the NI.
General information regarding the NI module's ASICs.
General information regarding the CPLD.
UBOOT version of the NI.
UBOOT-miniboot version of the NI.
POE software version of the NI (POE modules only).
The number of failed upgrade attempts (C20L modules that have
attempted to be upgraded only).
Reloads (i.e., reboots) a specified Network Interface (NI) module.
Turns the power on or off for a specified Network Interface (NI)
module.
Displays the basic information for either a specified module or all mod-
ules installed in the chassis.
Displays the detailed information for either a specified module or all
modules installed in the chassis.
Displays the basic status information for either a specified module or all
modules installed in the chassis.