Alcatel-Lucent OmniSwitch 6850-48 Cli Reference Manual page 3004

Alcatel-lucent omniswitch 6850-48: reference guide
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

Usage Guidelines
The command can be issued in any order like window, threshold, and notify. However, at least one
option needs to be entered.
To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame-period threshold 1 window 3000000 notify enable
-> efm-oam port 1/1 errored-frame-period notify disable
-> efm-oam port 2/1-4 errored-frame-period threshold 1 window 3000000 notify enable
-> efm-oam port 2/1-2 errored-frame-period notify disable
Release History
Release 6.4.2; command was introduced.
Related Commands
efm-oam errored-frame
efm-oam errored-frame-
seconds-summary
show efm-oam port detail
MIB Objects
dot3OamEventConfigTable
dot3OamErrFramePeriodWindow
dot3OamErrFramePeriodThreshold
dot3OamErrFramePeriodEvNotifEnable
page 46-18
Configures the threshold, window and notify-status for errored-
frame on a port. The frame-period measures the frame-errors,
within a specified window of time.
Configures the threshold, window and notify-status for errored-
frame-seconds-summary on a port. The Errored Seconds are the
time in seconds in which at least one frame error has occurred.
Displays the Errored Frame Period Event threshold, window, and
notification parameter values for a port.
LINK OAM Commands
OmniSwitch CLI Reference Guide
June 2012