Stack Set Slot - Alcatel-Lucent OmniSwitch 6850-48 Cli Reference Manual

Alcatel-lucent omniswitch 6850-48: reference guide
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

stack set slot

Sets the saved slot number or mode for stackable configuration switches. The saved slot number is the slot
position the switch will assume following a reboot. The stack set slot command also provides syntax for
immediately rebooting the corresponding switch.
stack set slot slot-number {saved-mode {OS6850E | OS6850} | saved-slot slot-number [reload]}
Syntax Definitions
slot-number
OS6850E | OS6850
saved-slot-number
reload
Defaults
parameter
saved-mode (Only supported on
OS6850E Models)
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855
Usage Guidelines
When the stack set slot command is issued, the new saved slot value is written to the boot.slot.cfg file.
This file is located in the switch's /flash directory and is used when assigning a slot number for the
switch during the boot process.
In order to avoid duplicate slot numbers within the virtual chassis—which can force one or more
switches into pass-though mode—be sure that the saved slot number being configured is not already
being used by another switch in the stack. To view the saved slot numbers currently assigned, use the
show stack topology
information on pass-through mode, refer to the Hardware Users Guide.
Changing the mode is only supported on OS6850E models. Mode must be set to OS6580 when stack-
ing with OS6580 switches and OS6850E when stacking with OS6855-U24X switches.
page 54-26
The current slot position used by the switch (1–8; 1001–1008). Note that
the valid slot number range also includes slot positions 1001 through
1008, reserved for switches in pass-through mode.
The stacking mode of the OS6850E.
The new (i.e., saved) slot number (1–8). The saved slot number is the
slot position the switch will assume following a reboot.
Optional command syntax. When reload is entered in the command
line, a confirmation prompt is issued. If the user approves the reload, the
corresponding switch will be rebooted immediately and the new
(i.e., saved) slot number will take effect when the switch comes back
up—barring any pass-though mode conditions, such as duplicate slot
numbers. This parameter is not supported when changing the mode.
default
6850
command. For detailed information on assigning saved slot numbers, as well as
Chassis Management and Monitoring Commands
OmniSwitch CLI Reference Guide
June 2012

Advertisement

Table of Contents
loading

Table of Contents