Chassis Management and Monitoring Commands
temp-threshold
Sets the warning temperature threshold for the switch.
temp-threshold temp slot slot-number
Syntax Definitions
temp
slot-number
Defaults
Refer to the appropriate Hardware Users Guide for platform specific temperature values.
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E.
Usage Guidelines
•
Use the
show temperature
old.
•
Do not use the
show health threshold
tion.
Examples
-> temp-threshold 45
-> temp-threshold 55 slot 2
Release History
Release 6.1; command was introduced.
Release 6.1.5; slot parameter added.
Related Commands
show temperature
MIB Objects
chasChassisTable
chasTempThreshold
OmniSwitch CLI Reference Guide
The new temperature threshold value, in Celsius.
The chassis slot number for which the warning temperature
threshold is set. This parameter is supported only on stackable switches.
command to display the current value for the temerpature warning thresh-
command as it does not display temperature threshold informa-
Displays the current operating chassis ambient temperature, as well as
current temperature threshold settings.
June 2012
page 54-25