reload issu

Upgrades the system with the images stored in the /flash/issu directory with minimal disruption to the data
traffic.
reload issu [in [hours:] minutes | at hour:minute]
Syntax Definitions
in [hours:] minutes
at hour:minute
Defaults
By default, the switch starts copying the image files to the working directory of the primary CMM imme-
diately after issuing the command if no time delay is specified.
Platforms Supported
OmniSwitch 9000E
Usage Guidelines
The switch must be running an In-Service Software Upgrade (ISSU) capable build, which is only those
builds that are part of the 'S##' branch (for example, 6.4.1.###.S01).
The primary and secondary CMMs should be fully synchronized, certified, redundant, and running an
ISSU capable 'S##' build, such as 6.4.1.123.S01, to invoke the ISSU feature.
Before using this command, create an ISSU directory on the switch flash (for example, /flash/issu),
then download the "S###" image files into this directory.
Image files used for the upgrade must be within the same 'S##' branch to pefrom an ISSU upgrade. For
example, 6.4.1.###.S02 image files cannot be used to upgrade a switch running 6.4.1.###/.S01.
There are four image files that are ISSU capable: Jbase.img, Jsecu.img, Jadvrout.img and Jos.img.
Admin user privileges are required to invoke the ISSU feature.
A minimum of 25MB flash space is required on the switch to accomodate all the image files needed for
the upgrade.
Once the images are upgraded, use the copy working certified flash-synchro command to restore
redundancy between the Primary and Secondary CMM.
Examples
-> reload issu
-> reload issu in 45
-> reload issu at 09:25
page 53-6
Optional syntax. Schedules a reload of the primary CMM to take effect
in the specified minutes or hours and minutes within the next 24 hours.
Optional syntax. Schedules a reload of the primary CMM to take place
at the specified time using a 24-hour clock.