Second Counter (Rseccnt); Minute Counter (Rmincnt) - Renesas RZ/A Series User Manual

Hide thumbs Also See for RZ/A Series:
Table of Contents

Advertisement

RZ/A1L Group, RZ/A1LU Group, RZ/A1LC Group
13.3.2

Second Counter (RSECCNT)

RSECCNT is the counter used for setting/counting the BCD-coded second value. The count operation is performed by a
carry for each second of the 64-Hz counter.
The assignable range is from 00 through 59 (practically in BCD); otherwise an operation error will occur. Carry out write
processing after stopping the count operation through the setting of the START bit in RCR2.
Bit
Bit Name
7
6 to 4
10 seconds
3 to 0
1 second
13.3.3

Minute Counter (RMINCNT)

RMINCNT is the counter used for setting/counting the BCD-coded minute value. The count operation is performed by a
carry for each minute of the second counter.
The assignable range is from 00 through 59 (practically in BCD); otherwise an operation error will occur. Carry out write
processing after stopping the count operation through the setting of the START bit in RCR2.
Bit
Bit Name
7
6 to 4
10 minutes
3 to 0
1 minute
R01UH0437EJ0600 Rev.6.00
Jan 29, 2021
BIt:
7
6
-
10 seconds
Initial value:
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
R/W:
R
R/W
Initial
Value
R/W
Description
0
R
Reserved
This bit is always read as 0. The write value should always be 0.
Undefined
R/W
Counting Ten's Position of Seconds
Counts from 0 to 5 for 60-seconds counting.
Undefined
R/W
Counting One's Position of Seconds
Counts from 0 to 9, one number per second. When a carry is generated, 1 is
added to the ten's position.
BIt:
7
6
-
10 minutes
Initial value:
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
R/W:
R
R/W
Initial
Value
R/W
Description
0
R
Reserved
This bit is always read as 0.The write value should always be 0.
Undefined
R/W
Counting Ten's Position of Minutes
Counts from 0 to 5 for 60-minutes counting.
Undefined
R/W
Counting One's Position of Minutes
Counts from 0 to 9, one number per minute. When a carry is generated, 1 is
added to the ten's position.
5
4
3
2
1
1 second
R/W
R/W
R/W
R/W
R/W
5
4
3
2
1
1 minute
R/W
R/W
R/W
R/W
R/W
13. Realtime Clock
0
R/W
0
R/W
13-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rz/a1 seriesRz/a1lu seriesRz/a1lc series

Table of Contents